PC4713-W-E-TY/R WiFi and Ethernet energy meter with three CT clamps and green relay output

PC4713-W-E-TY/R

Three-Phase WiFi + Ethernet Smart Energy Meter with Relay

Meter and switch over one cable — Tuya 3-phase meter with Ethernet and a 3 A dry-contact relay for lighting or HVAC loads.

Overview

PC4713-W-E-TY/R is the most complete model in the OWON three-phase Tuya range: three CT inputs, Wi-Fi, an Ethernet 10/100 Mbps port and a dry-contact relay in the same housing. Metering, switching and network reachability come from one device instead of three.

The relay is rated 3 A resistive and 5 A maximum with overload protection, and its real contact state is reported instantly rather than at the next data cycle. Ethernet and Wi-Fi operate together, so the meter stays reachable in a metal cabinet while Wi-Fi remains available for BLE-assisted setup.

Where the PC4713-W-E-TY/R Sits in the Range

Nothing further can be added within the Tuya line — this is the top of it. The decision below it is which single option to give up: the relay alone is on the PC4713-W-TY/R, the Ethernet port alone on the PC4713-W-E-TY, and neither on the PC4713-W-TY.

The two requirements it cannot meet are the ones that change platform rather than specification. A three-phase three-wire or delta service is metered by the PC4713-W-E-TY/3W, and a project that has to keep data on its own infrastructure rather than in the Tuya Cloud needs the PC4713 Open API series, PC4713-W or PC4713-W-485.

PC4713-W-E-TY/R Platform and Integration Notes

Reports into the Tuya Cloud, read in the Tuya App. Live values and history by day, week, month and year, with grid and energy values exportable to and importable from other Tuya devices — which is how the relay is switched by a scene rather than by hand.

Offline storage with automatic re-report. Readings are buffered locally and re-sent once a network path returns.

Reactive and apparent power on the home screen, not only active power, so a power-factor problem is visible on the first screen.

Standard Tuya DPs keep Home Assistant working. Standard data points are used wherever possible, with custom DPs only where needed.

PC4713-W-E-TY/R Limits and What to Specify Instead

  • Three-phase three-wire and delta — specify the PC4713-W-E-TY/3W.
  • Switching a three-phase load on the contacts — the dry contact is rated 3 A resistive / 5 A maximum and is intended for a small load or a contactor coil, with the three-phase load switched by that contactor.
  • Any destination other than the Tuya Cloud — the PC4713 Open API series is the self-hosted alternative.

Specifications

Accuracy±1% (Voltmeters)
Ammeter Accuracy80A CT: ±1% (1-80A), ±2% (0-1A); 120A CT: ±1% (2-120A), ±2% (0-2A); 200A CT: ±1% (2-200A), ±2% (0-2A); 300A CT: ±1% (6-300A), ±2% (2-6A), ±5% (0-2A); 500A CT: ±1% (6-500A), ±2% (2-6A), ±5% (0-2A); 750A CT: ±1% (6-750A), ±2% (2-6A), ±5% (0-2A)
Voltage90~277 Vac 50/60Hz (RMS per phase)
Current80A~750A (CT dependent)
Frequency50/60Hz
Power Supply<2W
ProtocolWiFi 802.11 b/g/n @ 2.4GHz + Ethernet 10/100 Mbps + BLE (pairing)
Wi-Fi802.11 b/g/n @ 2.4GHz
Ethernet10/100 Mbps
BLEFor Pairing
Relay TypeDry contact relay, resistive current rated 3A, max.5A, overload protection and relay setting
Supported SystemsSingle-Phase, Split-Phase, Three-Phase (3P3W & Delta not supported)
Mounting35mm DIN rail mounting
Dimensions19(W) x 69(D) x 90(H) mm
Operating Temp-20℃ to +55℃ (≤90% non-condensing)
Measured ParametersVoltage, Current, Power Factor, Frequency, Active Power, Reactive Power, Apparent Power; Energy Usage / Solar Production; relay on/off control
Reporting CycleEnergy data: every 15 seconds; relay status: immediately
Clamp Inner Dimension80A: Ø10mm; 120A (default): Ø16mm; 200A: Ø20mm; 300A: Ø24mm; 500A: Ø36mm; 750A: Ø51mm
CertificationCE
Place of OriginChina
BrandOWON

Key Benefits

Relay, Ethernet and Wi-Fi in One Module

Measures, switches and stays reachable: Wi-Fi and Ethernet run together, and the relay gives a control output on the same device.

Relay That Can Drive a Contactor

Dry contact rated 3 A resistive / 5 A maximum with overload protection — a small load directly, or an external contactor for a large one.

Data Export, Hour by Hour or Day by Day

Per-phase and per-sub-circuit energy can be exported — a single day hour by hour, or a date range day by day, up to one year.

Notification Alerts to the App

Alerts are pushed rather than discovered later, and the App carries German, French, Spanish and Italian as well as English.

Ideal For

Common deployment scenarios where Three-Phase WiFi + Ethernet Smart Energy Meter with Relay delivers the most value.

Commercial Energy Management

Ethernet stability plus relay control for facility-wide energy management.

Remote Load On/Off Control

Turn loads on/off remotely via the dry-contact relay from the Tuya App.

Solar PV Self-Consumption

Bidirectional measurement tracks generation and consumption across the phases.

Demand Response Programs

Relay control enables load shedding and demand response on three-phase supplies.

Whole-Home Energy Monitoring

Three CT clamps monitor the entire installation on single, split or three-phase supplies.

OEM / ODM Projects

OEM branding and ODM development available for distributors and integrators.

Frequently Asked Questions

What makes the PC4713-W-E-TY/R different from other PC4713 variants?
It is the most complete: Wi-Fi and Ethernet connectivity and the dry-contact relay in the same unit.
Do the relay and the Ethernet port interfere with each other?
No. The relay is a local dry-contact output; the network path and the metering are independent of it, so switching a load does not disturb reporting.
Can I export the per-circuit history, not just a total?
Yes. Export covers per-phase and per-sub-circuit energy: a single day hour by hour, or a date range day by day, over a one-year window.
If the network is down for a week, does the record have a hole in it?
No. Readings are buffered locally and re-sent automatically once the network returns, so an outage leaves a gap in the live view, not in the record.
Which CT rating fits a 400 A three-phase feeder?
The 500 A clamp (Ø36 mm) — a 400 A feeder is above the 300 A clamp. The range runs 80 to 750 A in six bores, and because accuracy is banded per rating, going up a clamp size does not degrade the reading at working current.
Does it need a gateway?
No. Wi-Fi and Ethernet connect directly; a gateway is only needed for ZigBee devices.
Will the facility team be told, or must someone watch the App?
Alerts are pushed to the App rather than left in a chart, and the App covers German, French, Spanish and Italian as well as English.
Does the relay affect the metering accuracy?
No. Voltage ±1%; current ±1% at rated current and ±2% at low current, banded per clamp.
Can it be upgraded to the Open API version later?
No. Different hardware, not a firmware change.

PC4713 Series — choose the right variant

PC4713-WWiFi + open protocol (HTTP / MQTT / Modbus TCP)
PC4713-W-TYWiFi + Tuya Cloud
PC4713-W-TY/R+ dry-contact relay (remote on/off)
PC4713-W-E-TY+ wired Ethernet 10/100
PC4713-W-E-TY/R — this page+ Ethernet + dry-contact relay
PC4713-W-E-TY/3W3-phase 3-wire (3P3W) supplies
PC4713-W-485+ RS485 Modbus RTU (BMS / SCADA)

Not sure which variant fits your project? See the PC471 selection guide.

Related Products

Interested in Three-Phase WiFi + Ethernet Smart Energy Meter with Relay?

Download the datasheet or request pricing — our team will respond within 24 hours.

Our engineers usually reply within one business day.