PC4713-W-TY/R
Three-Phase WiFi Smart Energy Meter with Relay
Schedule power-down: Tuya 3-phase meter with 3 A relay, per-phase kWh, voltage and current logged on a 35 mm DIN rail.
Overview
PC4713-W-TY/R is the three-phase Tuya meter that can act as well as report. It adds a dry-contact relay — 3 A resistive, 5 A maximum, with overload protection — to the Wi-Fi metering core of the PC4713-W-TY.
The relay switches a small load directly, or drives an external contactor when the load is larger or the circuit is three-phase. Relay status is reported to the App immediately, so a control action is confirmed at once instead of at the next data cycle, which is what makes threshold-based switching on measured power workable in practice.
Where the PC4713-W-TY/R Sits in the Range
The relay is the reason to choose this model over the PC4713-W-TY; three CT inputs, Wi-Fi, the Tuya platform and the export and erase behaviour are all shared. Ethernet is not fitted here — the PC4713-W-E-TY/R is the model that carries the relay and the wired port together.
Two requirements sit outside the Tuya line. A three-phase three-wire or delta service needs the PC4713-W-E-TY/3W, and reporting into your own cloud or local server needs the PC4713 Open API hardware, PC4713-W or PC4713-W-485.
PC4713-W-TY/R Platform and Integration Notes
Reports into the Tuya Cloud, read in the Tuya App. Live values plus history by day, week, month and year. Grid and energy values can be exported to and imported from other Tuya devices, which is how the relay is driven by a scene rather than only by hand.
Offline storage with automatic re-report. Readings are held locally and re-sent after the network returns, so a dropout does not leave a hole in the record.
Notification and language coverage. Alerts are pushed to the App, which carries German, French, Spanish and Italian as well as English.
Reactive and apparent power on the home screen, so power factor is visible without opening a chart.
Standard Tuya DPs keep Home Assistant working. Standard data points wherever possible, custom DPs only where needed.
PC4713-W-TY/R Limits and What to Specify Instead
- Ethernet — not fitted. The PC4713-W-E-TY/R carries the relay and the wired port together.
- Three-phase three-wire and delta — the PC4713-W-E-TY/3W is built for that supply.
- Switching a three-phase load on the contacts — the rating suits a small load or a contactor coil; the three-phase circuit is switched through that contactor.
- Any destination other than the Tuya Cloud — the Open API series is the self-hosted route.
Specifications
| Accuracy | ±1% (Voltmeters) |
|---|---|
| Ammeter Accuracy | 80A CT: ±1% (1-80A), ±2% (0-1A); 120A CT: ±1% (2-120A), ±2% (0-2A); 200A CT: ±1% (2-200A), ±2% (0-2A); 300A CT: ±1% (6-300A), ±2% (2-6A), ±5% (0-2A); 500A CT: ±1% (6-500A), ±2% (2-6A), ±5% (0-2A); 750A CT: ±1% (6-750A), ±2% (2-6A), ±5% (0-2A) |
| Voltage | 90~277 Vac 50/60Hz (RMS per phase) |
| Current | 80A~750A (CT dependent) |
| Frequency | 50/60Hz |
| Power Supply | <2W |
| Protocol | WiFi 802.11 b/g/n @ 2.4GHz + BLE (pairing) |
| Wi-Fi | 802.11 b/g/n @ 2.4GHz |
| BLE | For Pairing |
| Relay Type | Dry contact relay, resistive current rated 3A, max.5A, overload protection and relay setting |
| Supported Systems | Single-Phase, Split-Phase, Three-Phase (3P3W & Delta not supported) |
| Mounting | 35mm DIN rail mounting |
| Dimensions | 19(W) x 69(D) x 90(H) mm |
| Operating Temp | -20℃ to +55℃ (≤90% non-condensing) |
| Measured Parameters | Voltage, Current, Power Factor, Frequency, Active Power, Reactive Power, Apparent Power; Energy Usage / Solar Production; relay on/off control |
| Reporting Cycle | Energy data: every 15 seconds; relay status: immediately |
| Clamp Inner Dimension | 80A: Ø10mm; 120A (default): Ø16mm; 200A: Ø20mm; 300A: Ø24mm; 500A: Ø36mm; 750A: Ø51mm |
| Certification | CE |
| Place of Origin | China |
| Brand | OWON |
Key Benefits
Relay That Can Drive a Contactor
The dry contact is rated 3 A resistive / 5 A maximum with overload protection: switch a small load directly, or drive an external contactor for a large one.
Relay Status Reported Instantly
The App shows the real contact state, not the state at the last 15-second data cycle.
Data Export, Hour by Hour or Day by Day
Per-phase and per-sub-circuit energy can be exported — a single day hour by hour, or a date range day by day, up to one year.
Erase Data and Re-Range CTs Without a Visit
Data erase keeps the network pairing, and the CT setting can be changed from the App at any time.
Ideal For
Common deployment scenarios where Three-Phase WiFi Smart Energy Meter with Relay delivers the most value.
Remote Load On/Off Control
Turn water heaters, EV chargers or lighting on/off remotely via the dry-contact relay.
Solar PV Self-Consumption
Bidirectional measurement tracks generation and consumption; relay can shed load.
Smart Home Automation
Tuya ecosystem automation — schedule and control the relay alongside other devices.
Demand Response & Load Management
Energy data plus relay control enable demand-response and load-shedding programs.
Commercial & Residential Installations
Three-phase, split-phase and single-phase monitoring with DIN-rail mounting.
OEM / ODM Projects
OEM branding and ODM development available for distributors and integrators.
Frequently Asked Questions
Can the relay switch a three-phase pump directly?
Can it switch automatically on a measured threshold?
How does the App report a relay action?
How is the relay protected?
Does the relay affect the metering accuracy?
Which CT ratings and apertures are available?
Can I export data, and how long is history kept?
Can it be upgraded to the Open API version later?
After the meter is sealed, can the CT range or the stored data still be changed?
PC4713 Series — choose the right variant
| PC4713-W | WiFi + open protocol (HTTP / MQTT / Modbus TCP) |
|---|---|
| PC4713-W-TY | WiFi + Tuya Cloud |
| PC4713-W-TY/R — this page | + dry-contact relay (remote on/off) |
| PC4713-W-E-TY | + wired Ethernet 10/100 |
| PC4713-W-E-TY/R | + Ethernet + dry-contact relay |
| PC4713-W-E-TY/3W | 3-phase 3-wire (3P3W) supplies |
| PC4713-W-485 | + RS485 Modbus RTU (BMS / SCADA) |
Not sure which variant fits your project? See the PC471 selection guide.
Related Products
Interested in Three-Phase WiFi Smart Energy Meter with Relay?
Download the datasheet or request pricing — our team will respond within 24 hours.
Our engineers usually reply within one business day.