PC4713-W-E-TY/3W three-phase 3-wire energy meter with three split-core CT clamps on leads

PC4713-W-E-TY/3W

Three Phase WiFi + Ethernet Smart Energy Meter

Built for 3-phase 3-wire and Delta supplies (156-480 V L-L): Tuya metering over Ethernet or WiFi, three 750 A CTs, bidirectional energy.

Overview

PC4713-W-E-TY/3W is the one model in the OWON three-phase range built for a three-phase three-wire or delta supply. The other six are specified for three-phase four-wire; this one covers that as well as split-phase and single-phase, so a single SKU spans every common supply arrangement.

It is also the model the case change came with: a 1P DIN module 19 mm wide, 19 × 69 × 90 mm overall, for boards in the European market. Its voltage window is the widest in the range — 90–277 Vac line-to-neutral and 156–480 Vac line-to-line — with bidirectional measurement on three CTs from 80 A to 750 A.

Where the PC4713-W-E-TY/3W Sits in the Range

This model exists because a three-phase three-wire or delta service cannot be metered by hardware designed around four-wire measurement, and the rest of the Tuya line is four-wire hardware. Where a project is on a four-wire supply, the PC4713-W-E-TY/R is the fuller specification — it adds the dry-contact relay to the same Ethernet and Wi-Fi connectivity.

The 3W build is also the narrowest case in the family, at 19 mm on the rail, for boards where a wider instrument will not fit. As with the other Tuya models, the data destination is fixed at the Tuya Cloud; keeping readings on your own server means the PC4713 Open API series, PC4713-W or PC4713-W-485.

PC4713-W-E-TY/3W Platform and Integration Notes

Reports into the Tuya Cloud, read in the Tuya App. Live values and history by day, week, month and year, with grid and energy values exportable to and importable from other Tuya devices for automation.

Offline storage with automatic re-report. Readings are held locally and re-sent once a network path returns, so a dropout does not become a gap in the record.

Notification and language coverage. Alerts are pushed to the App, which is available in German, French, Spanish and Italian as well as English — the languages a European installation is most likely to need.

Reactive and apparent power on the home screen, so power factor is visible without opening a report.

Standard Tuya DPs keep Home Assistant working. Standard data points are used wherever possible, with custom DPs only where needed.

PC4713-W-E-TY/3W Limits and What to Specify Instead

  • Relay output — not fitted. Load switching is available on the PC4713-W-E-TY/R and PC4713-W-TY/R.
  • Any destination other than the Tuya Cloud — the PC4713 Open API series reports to your own cloud or local server.
  • RS485 / Modbus RTU — not offered in the Tuya range. The PC4713-W-485 carries the serial bus.

Packaging & Delivery

  • Selling Units: Single item

Specifications

Accuracy±1% (Voltmeters); Ammeters: ±1% (1-80A) / ±2% (0-1A) depending on CT rating
VoltageL-N: 90~277 Vac 50/60Hz; L-L: 156~480 Vac 50/60Hz
Current80A~750A (CT dependent)
Frequency50/60Hz
Power Supply<2W
ProtocolWiFi 802.11 b/g/n @ 2.4GHz + BLE (pairing) + Ethernet 10/100 Mbps
Dimensions19(W) x 69(D) x 90(H) mm
Mounting35mm DIN rail mounting
Operating Temp-20℃ to +55℃ (≤90% non-condensing)
Measured ParametersVoltage, Current, Power Factor, Frequency, Active Power, Reactive Power, Apparent Power
Reporting CycleEvery 15 seconds
CertificationCE
Place of OriginChina
BrandOWON
Supported SystemsSingle-Phase, Split-Phase, Three-Phase (included 3-Phase 3-Wire)
Clamp Inner Dimension80A: Ø10mm; 120A (default): Ø16mm; 200A: Ø20mm; 300A: Ø24mm; 500A: Ø36mm; 750A: Ø51mm
Ammeter Accuracy80A CT: ±1% (1-80A), ±2% (0-1A); 120A CT: ±1% (2-120A), ±2% (0-2A); 200A CT: ±1% (2-200A), ±2% (0-2A); 300A CT: ±1% (6-300A), ±2% (2-6A), ±5% (0-2A); 500A CT: ±1% (6-500A), ±2% (2-6A), ±5% (0-2A); 750A CT: ±1% (6-750A), ±2% (2-6A), ±5% (0-2A)
Wi-Fi802.11 b/g/n @ 2.4GHz
BLEFor Pairing
Ethernet10/100 Mbps

Wiring & installation

Filmed on a live panel: three phases with no neutral, L1 to A, L2 to B, L3 to C, and only two CTs on IA+/- and IC+/- — the middle phase carries no clamp.

Isolate the supply before touching any conductor. Wire colours in the clip are the demo panel's, not a requirement.

Numbered steps, the terminal table and the mistakes that happen on site: full wiring tutorial .

Key Benefits

1P (19 mm) Case for European Boards

A single DIN module, 19 mm wide and 19 x 69 x 90 mm overall, with plug-in power and CT terminals so the unit can be mounted first and wired after.

3P3W, Delta and 3P4W Hardware

The one model in the range built for three-phase three-wire and delta supplies, and it also covers three-phase four-wire, split-phase and single-phase.

Wi-Fi and Ethernet Running Together

Both links active at once — Wi-Fi where cabling is impossible, Ethernet where wireless is poor.

Data Export and Data Erase Without Re-Pairing

Export per-phase energy hour by hour within a day or day by day across a range, up to one year; erase stored data while keeping the Wi-Fi pairing.

Ideal For

Common deployment scenarios where Three Phase WiFi + Ethernet Smart Energy Meter delivers the most value.

Solar PV Self-Consumption

Monitor generation and consumption in real time with bi-directional metering — see exactly how much solar you export vs. use.

Home Energy Management

Track whole-home energy across three phases via the Tuya / Smart Life app, with historical data by day, week, month, and year.

Three-Phase Motor Monitoring

Supports 3P3W and 3P4W wiring — ideal for monitoring three-phase motor loads and industrial equipment.

Regions Using 3-Phase 3-Wire Lines

Works with three-phase three-wire grids (common in some countries) as well as the standard three-phase four-wire system.

Commercial & Industrial Submetering

DIN-rail 1P 19 mm form factor fits tight distribution boards for per-circuit or per-machine energy allocation.

Energy Storage Systems

Bi-directional measurement tracks charging and discharging of battery storage alongside solar generation.

Frequently Asked Questions

Which supply arrangements does the 3W actually cover?
Three-phase three-wire (delta), three-phase four-wire, split-phase and single-phase. The voltage window is the widest in the range: 90-277 Vac line-to-neutral and 156-480 Vac line-to-line, which is what the delta connection needs.
Why is it only 1P (19 mm) wide, and will it fit a European board?
European boards were the driver for this mould: a 1P module, 19 x 69 x 90 mm on 35 mm DIN rail, fits where a wider instrument will not.
The terminals are plug-in — what does that change on site?
Power and CT connections are made through removable male/female terminal blocks, so the main unit can be fixed and wired first and the terminal blocks inserted afterwards — useful when panel work is done in stages.
How do I commission the network the first time?
Download the Smart Life app, then either scan the QR code on the device or use Bluetooth pairing. For Wi-Fi you need the 2.4 GHz network name and password; for Ethernet, plug in an internet-enabled cable. If no device is detected, press and hold Reset for 5 seconds until the Net LED blinks slowly, then try again.
Which CT ratings and apertures are available?
80 to 750 A in six steps, with bores of Ø10 / 16 / 20 / 24 / 36 / 51 mm. This model uses three clamps.
How accurate is it?
Voltage ±1%; current ±1% at rated current and ±2% at low current, banded per clamp.
Should I take this or the PC4713-W-E-TY/R?
By the supply. On a three-phase three-wire or delta service only this model works — the four-wire hardware cannot meter it. On a four-wire board that also needs the dry-contact relay, the PC4713-W-E-TY/R is the fuller specification.
Is the App localised for European installers?
Yes. German, French, Spanish and Italian in addition to English, and alerts are pushed to the App.
Does it need a gateway?
No. Wi-Fi or Ethernet connect directly; a gateway is only needed for ZigBee devices.

PC4713 Series — choose the right variant

PC4713-WWiFi + open protocol (HTTP / MQTT / Modbus TCP)
PC4713-W-TYWiFi + Tuya Cloud
PC4713-W-TY/R+ dry-contact relay (remote on/off)
PC4713-W-E-TY+ wired Ethernet 10/100
PC4713-W-E-TY/R+ Ethernet + dry-contact relay
PC4713-W-E-TY/3W — this page3-phase 3-wire (3P3W) supplies
PC4713-W-485+ RS485 Modbus RTU (BMS / SCADA)